Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Perinatol ; 32(11): 837-43, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22441115

RESUMO

OBJECTIVE: To describe maternal and perinatal morbidity and mortality associated with uterine rupture (UR) among women with prior cesarean/s, singleton term pregnancies and a trial of labor after cesarean (TOLAC). STUDY DESIGN: Linked hospital discharge files and birth/fetal death certificates identified potential cases of UR in Massachusetts from 1990 to 1998 with definitive identification by medical record abstraction. RESULT: Among the 347 identified URs, severe outcomes occurred in 86 cases (25%), in 49 (14%) of mothers and 49 (14%) of infants. Of the infants, 25 were discharged with a good prognosis. Maternal age and interdelivery interval <18 months (relative risk (RR)=1.55; 95% confidence interval (CI): 1.05, 2.31) were associated with a severe outcome. The type of hospital and labor were not associated with the increased risk of a severe outcome. CONCLUSION: Assuming a 0.7% UR rate among women at term with a TOLAC, the increased rate of severe outcomes related to UR above the baseline risk of elective cesarean is estimated to be 1.3 per 1000 TOLACs.


Assuntos
Mortalidade Infantil , Morte Materna/estatística & dados numéricos , Prova de Trabalho de Parto , Ruptura Uterina/mortalidade , Nascimento Vaginal Após Cesárea , Índice de Apgar , Feminino , Humanos , Recém-Nascido , Massachusetts/epidemiologia , Idade Materna , Gravidez , Prognóstico , Fatores de Risco , Ruptura Uterina/epidemiologia
2.
Phys Rev Lett ; 97(1): 012501, 2006 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-16907369

RESUMO

The gamma decay of the giant dipole resonance (GDR) in the 132Ce compound nucleus with temperature up to approximately 4 MeV has been measured, using the reaction 64Ni + 68Zn at E(beam) = 300, 400, and 500 MeV. The gamma and charged particles measured in coincidence with recoils are consistent with a fully equilibrated compound nucleus emission. The GDR width, obtained with the statistical model analysis, is found to increase almost linearly with temperature. This increase is rather well reproduced within a model including thermal shape fluctuations and the lifetime of the compound nucleus.

3.
Phys Med ; 17 Suppl 1: 124-7, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11770527

RESUMO

The use of existing detecting systems developed for nuclear physics studies allows collecting data on particle and ion production cross-sections in reactions induced by Oxygen and Carbon beams, of interest for hadrontherapy and heavy-ion risk assessment. The MULTICS and GARFIELD apparatus, together with the foreseen experiments, are reviewed.


Assuntos
Carbono , Íons Pesados , Oxigênio , Monitoramento de Radiação/instrumentação , Desenho de Equipamento , Raios gama , Itália , Física Nuclear , Monitoramento de Radiação/métodos , Radioterapia , Medição de Risco , Voo Espacial
5.
8.
Phys Rev C Nucl Phys ; 47(2): 521-528, 1993 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9968467
10.
Phys Rev C Nucl Phys ; 44(4): 1508-1514, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9967555
11.
Phys Rev C Nucl Phys ; 41(3): 1167-1171, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9966457
13.
Phys Rev C Nucl Phys ; 36(6): 2528-2532, 1987 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9954377
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...